Same-Day Shipping 40th Anniversary 10,000+ 5-Star Reviews
Same-Day Shipping
40th Anniversary
10,000+ 5-Star Reviews

  • Canada (CAD $)
  • France (EUR €)
  • United Kingdom (GBP £)
  • United States (USD $)
  • Afghanistan (AFN ؋)
  • Åland Islands (EUR €)
  • Albania (ALL L)
  • Algeria (DZD د.ج)
  • Andorra (EUR €)
  • Angola (USD $)
  • Anguilla (XCD $)
  • Antigua & Barbuda (XCD $)
  • Argentina (USD $)
  • Armenia (AMD դր.)
  • Aruba (AWG ƒ)
  • Ascension Island (SHP £)
  • Australia (AUD $)
  • Austria (EUR €)
  • Azerbaijan (AZN ₼)
  • Bahamas (BSD $)
  • Bahrain (USD $)
  • Bangladesh (BDT ৳)
  • Barbados (BBD $)
  • Belarus (USD $)
  • Belgium (EUR €)
  • Belize (BZD $)
  • Benin (XOF Fr)
  • Bermuda (USD $)
  • Bhutan (USD $)
  • Bolivia (BOB Bs.)
  • Bosnia & Herzegovina (BAM КМ)
  • Botswana (BWP P)
  • Brazil (USD $)
  • British Indian Ocean Territory (USD $)
  • British Virgin Islands (USD $)
  • Brunei (BND $)
  • Bulgaria (EUR €)
  • Burkina Faso (XOF Fr)
  • Burundi (BIF Fr)
  • Cambodia (KHR ៛)
  • Cameroon (XAF CFA)
  • Cape Verde (CVE $)
  • Caribbean Netherlands (USD $)
  • Cayman Islands (KYD $)
  • Central African Republic (XAF CFA)
  • Chad (XAF CFA)
  • Chile (USD $)
  • China (CNY ¥)
  • Christmas Island (AUD $)
  • Cocos (Keeling) Islands (AUD $)
  • Colombia (USD $)
  • Comoros (KMF Fr)
  • Congo - Brazzaville (XAF CFA)
  • Congo - Kinshasa (CDF Fr)
  • Cook Islands (NZD $)
  • Costa Rica (CRC ₡)
  • Côte d’Ivoire (XOF Fr)
  • Croatia (EUR €)
  • Curaçao (ANG ƒ)
  • Cyprus (EUR €)
  • Czechia (CZK Kč)
  • Denmark (DKK kr.)
  • Djibouti (DJF Fdj)
  • Dominica (XCD $)
  • Dominican Republic (DOP $)
  • Ecuador (USD $)
  • Egypt (EGP ج.م)
  • El Salvador (USD $)
  • Equatorial Guinea (XAF CFA)
  • Eritrea (USD $)
  • Estonia (EUR €)
  • Eswatini (USD $)
  • Ethiopia (ETB Br)
  • Falkland Islands (FKP £)
  • Faroe Islands (DKK kr.)
  • Fiji (FJD $)
  • Finland (EUR €)
  • French Guiana (EUR €)
  • French Polynesia (XPF Fr)
  • French Southern Territories (EUR €)
  • Gabon (XOF Fr)
  • Gambia (GMD D)
  • Georgia (USD $)
  • Germany (EUR €)
  • Ghana (USD $)
  • Gibraltar (GBP £)
  • Greece (EUR €)
  • Greenland (DKK kr.)
  • Grenada (XCD $)
  • Guadeloupe (EUR €)
  • Guatemala (GTQ Q)
  • Guernsey (GBP £)
  • Guinea (GNF Fr)
  • Guinea-Bissau (XOF Fr)
  • Guyana (GYD $)
  • Haiti (USD $)
  • Honduras (HNL L)
  • Hong Kong SAR (HKD $)
  • Hungary (HUF Ft)
  • Iceland (ISK kr)
  • India (INR ₹)
  • Indonesia (IDR Rp)
  • Iraq (USD $)
  • Ireland (EUR €)
  • Isle of Man (GBP £)
  • Israel (ILS ₪)
  • Italy (EUR €)
  • Jamaica (JMD $)
  • Japan (JPY ¥)
  • Jersey (USD $)
  • Jordan (USD $)
  • Kazakhstan (KZT ₸)
  • Kenya (KES KSh)
  • Kiribati (USD $)
  • Kosovo (EUR €)
  • Kuwait (USD $)
  • Kyrgyzstan (KGS som)
  • Laos (LAK ₭)
  • Latvia (EUR €)
  • Lebanon (LBP ل.ل)
  • Lesotho (USD $)
  • Liberia (USD $)
  • Libya (USD $)
  • Liechtenstein (CHF CHF)
  • Lithuania (EUR €)
  • Luxembourg (EUR €)
  • Macao SAR (MOP P)
  • Madagascar (USD $)
  • Malawi (MWK MK)
  • Malaysia (MYR RM)
  • Maldives (MVR MVR)
  • Mali (XOF Fr)
  • Malta (EUR €)
  • Martinique (EUR €)
  • Mauritania (USD $)
  • Mauritius (MUR ₨)
  • Mayotte (EUR €)
  • Mexico (USD $)
  • Moldova (MDL L)
  • Monaco (EUR €)
  • Mongolia (MNT ₮)
  • Montenegro (EUR €)
  • Montserrat (XCD $)
  • Morocco (MAD د.م.)
  • Mozambique (USD $)
  • Myanmar (Burma) (MMK K)
  • Namibia (USD $)
  • Nauru (AUD $)
  • Nepal (NPR Rs.)
  • Netherlands (EUR €)
  • New Caledonia (XPF Fr)
  • New Zealand (NZD $)
  • Nicaragua (NIO C$)
  • Niger (XOF Fr)
  • Nigeria (NGN ₦)
  • Niue (NZD $)
  • Norfolk Island (AUD $)
  • North Macedonia (MKD ден)
  • Norway (USD $)
  • Oman (USD $)
  • Pakistan (PKR ₨)
  • Palestinian Territories (ILS ₪)
  • Panama (USD $)
  • Papua New Guinea (PGK K)
  • Paraguay (PYG ₲)
  • Peru (PEN S/)
  • Philippines (PHP ₱)
  • Pitcairn Islands (NZD $)
  • Poland (PLN zł)
  • Portugal (EUR €)
  • Qatar (QAR ر.ق)
  • Réunion (EUR €)
  • Romania (RON Lei)
  • Rwanda (RWF FRw)
  • Samoa (WST T)
  • San Marino (EUR €)
  • São Tomé & Príncipe (STD Db)
  • Saudi Arabia (SAR ر.س)
  • Senegal (XOF Fr)
  • Serbia (RSD РСД)
  • Seychelles (USD $)
  • Sierra Leone (SLL Le)
  • Singapore (SGD $)
  • Sint Maarten (ANG ƒ)
  • Slovakia (EUR €)
  • Slovenia (EUR €)
  • Solomon Islands (SBD $)
  • Somalia (USD $)
  • South Africa (USD $)
  • South Georgia & South Sandwich Islands (GBP £)
  • South Korea (KRW ₩)
  • South Sudan (USD $)
  • Spain (EUR €)
  • Sri Lanka (LKR ₨)
  • St. Barthélemy (EUR €)
  • St. Helena (SHP £)
  • St. Kitts & Nevis (XCD $)
  • St. Lucia (XCD $)
  • St. Martin (EUR €)
  • St. Pierre & Miquelon (EUR €)
  • St. Vincent & Grenadines (XCD $)
  • Sudan (USD $)
  • Suriname (USD $)
  • Svalbard & Jan Mayen (USD $)
  • Sweden (SEK kr)
  • Switzerland (CHF CHF)
  • Taiwan (TWD $)
  • Tajikistan (TJS ЅМ)
  • Tanzania (TZS Sh)
  • Thailand (THB ฿)
  • Timor-Leste (USD $)
  • Togo (XOF Fr)
  • Tokelau (NZD $)
  • Tonga (TOP T$)
  • Trinidad & Tobago (TTD $)
  • Tristan da Cunha (GBP £)
  • Tunisia (USD $)
  • Türkiye (USD $)
  • Turkmenistan (USD $)
  • Turks & Caicos Islands (USD $)
  • Tuvalu (AUD $)
  • U.S. Outlying Islands (USD $)
  • Uganda (UGX USh)
  • Ukraine (UAH ₴)
  • United Arab Emirates (AED د.إ)
  • Uruguay (UYU $U)
  • Uzbekistan (UZS so'm)
  • Vanuatu (VUV Vt)
  • Vatican City (EUR €)
  • Venezuela (USD $)
  • Vietnam (VND ₫)
  • Wallis & Futuna (XPF Fr)
  • Western Sahara (MAD د.م.)
  • Yemen (YER ﷼)
  • Zambia (USD $)
  • Zimbabwe (USD $)
+1 405.745.4054

Programmable Plating Rectifiers: 60A & 80A

DIGITAL PRECISION / 60A & 80A

Programmable
plating
rectifiers.

Built around your process.
Ready for your next batch.

Run up to five stored programs in sequence, track amp-hours, or use continuous manual mode for extended plating and electroforming runs.

60A from $1,95080A · $2,250 USD
THE 80A DIGITAL PRECISION270.80A
Pepetools Digital Precision rectifier with digital display, control dial, transparent front panel and polarity terminals
80A max · 18V max · 950W limit
15.75 × 9.84 in footprint6 kg
80A

Current capacity

5

Programs in sequence

Ah

Integrated counter

RUN

Continuous manual mode

80A MODEL
AT A GLANCE

01 / PROCESS CONTROL

More than
amps and volts.

A rectifier is part of a larger process. Choose controls that help you define the electrical conditions of your work, then validate the finish with your chemistry and setup.

01 — PROGRAM

Define your sequence.

Store five programs and arrange up to five program steps in a sequence, including repeated programs. Each program has voltage, current-limit, plating-time, reverse-time and end-of-program-delay settings.

02 — TRACK

Make amp-hours visible.

Track transferred charge with the integrated amp-hour counter. Reset the counter before a batch to measure that run, or retain the accumulated total for your bath supplier’s maintenance guidance.

03 — KEEP RUNNING

Run on your schedule.

Manual mode supports continuous operation without a programmed time limit. Set voltage and current limit, control polarity, and start or stop the output manually. Power and thermal limits still apply.

Amp-hours measure charge, not coating thickness. Deposit quality also depends on chemistry, surface preparation, current density and operating conditions.

02 / EXPLORE APPLICATIONS

Different work.
A common need for control.

Explore applications where controlled DC power matters. Share your bath’s current, voltage and timing requirements to confirm the right model.

01

Jewelry manufacturing

Evaluate capacity for racks of chains, findings, pendants and other jewelry components. Programmable outputs and amp-hour tracking bring useful control to recurring batches.

Size by batch surface area
02

Contract & small-batch plating

Assess a compact rectifier for a dedicated tank, development line or secondary station. Match the unit to the bath, load and operating schedule.

Review the operating specs
03

Decorative hardware

Explore power requirements for fittings, handles, trim and accessory components. Larger or more numerous parts can change the current your batch needs.

Estimate required current
04

Electroforming studios

Continuous manual operation supports extended copper electroforming runs. For staged processes, sequence up to five programs with different electrical and timing settings. Match the supply to your bath and workpiece.

Read the electroforming notes
05

PCB copper via filling & R&D

Sequence stored programs for staged copper via-fill development, sample parts and process trials. Set each stage to match your chemistry supplier’s qualified DC or timed polarity-reversal process.

Explore sequential control
06

Watch & precision components

For small parts and delicate work, start with the minimum current and resolution you need. A lower-capacity IPS model may be the more appropriate choice.

Compare Pepetools capacities

Have a different application? Share your bath chemistry, total plated area, current density and required voltage with our team.

Discuss your process

03 / THE COMPARISON

Choose for your process.
Compare the details.

A basic rectifier, a compact programmable unit and a specialized power pack solve different needs. Here is how selected options compare.

Pepetools 80A highlightedUSD prices checked October 29, 2026

Swipe across to compare all four options

Pepetools 80A compared with Caswell RECT30, Aldonex 100A and SIFCO TechnoPlate 60A
What matters COMPACT + PROGRAMMABLEPepetoolsDigital Precision 80AProduct source ↗ BASIC CONTROLCaswellRECT30Product source ↗ HIGHER CURRENTAldonex100A / 12V · via CaswellSeller source ↗ SELECTIVE PLATINGSIFCOTechnoPlate 60A / 20VProduct source ↗
Advertised price $2,250 $461.55 $6,883.61 Request quote
Rated output 80A max / 18V max
950W total power limit
0–30A / 0–20V 100A / 12V 60A / 20V
Programming 5 stored programs; up to 5 sequence steps, including repeats Not stated in linked listing Not stated in linked listing Up to 99 stored steps; operator advances between steps ↗
Amp-hour feature Integrated amp-hour counter Not stated in linked listing Not stated in linked listing Ampere-hour alarms
Polarity control One-button reverse polarity Not stated in linked listing Not stated in linked listing Pole changer; reverse alarms
Size & weight Approx. 15.75 L × 9.84 W × 5.31 H in
400 × 250 × 135 mm
6 kg / 13.2 lb
13 W × 8 H × 8.5 in
23 lb / 10.4 kg
Not stated in linked listing 30 lb / 13.6 kg
Dimensions not stated
Input Automatic 110/220V Not stated in linked listing 110V, single phase 115/230V
Before you choose Continuous manual mode plus timed programs. Match the load to the 950W limit and your chemistry. Seller states no constant-current mode; unsuitable for anodizing. Request details on controls, operating requirements and enclosure. Designed for selective / brush plating. Output leads sold separately.

Selected models, not a market ranking. Specifications and configurations differ. “Not stated” means the linked listing does not establish the feature; it does not mean the feature is absent.

Advertised prices in USD; tax and shipping additional. Confirm current pricing and specifications with each supplier. Brand names belong to their respective owners. Weight conversions are approximate.

See which Pepetools model to consider

04 / SIZE YOUR REQUIREMENT

How many amps
does your batch need?

Start with total plated surface area and the current density specified by your chemistry supplier. Tank volume alone does not tell you the current requirement.

Surface area×Current density=Required current

This estimates current only. The 80A model has a 950W total power limit: check current × required voltage as well as the current and voltage limits. Confirm the separate 60A ratings with Pepetools.

Batch current estimator

A
A/dm²
YOUR ESTIMATED CURRENT— A

Enter both values to estimate the current for your batch.

05 / CHOOSE YOUR CAPACITY

The right amount
of possibility.

Match the power supply to your process. Explore the high-current range, or start with IPS for smaller current requirements.

DIGITAL PRECISION60A & 80A

Room for a bigger batch.

Stored programs, sequential execution, continuous manual operation, an amp-hour counter and polarity control.

$2,250 USD

80A max · 18V max · 950W limit · SKU 270.80A

View 80A at Pepetools

Includes power cord, instructions and heavy-duty alligator-clip leads.

INTELLIGENT PLATING SYSTEM

Smaller process?
Meet IPS.

The Pepetools IPS range offers lower-capacity programmable rectifiers with amp-hour tracking. Compare the voltage as well as the amperage.

10A12V18A18V25A12V

IPS PLUS provides programmable plating control. IPS PRO adds a programmable solution heater.

Explore the IPS range

Prices shown in USD, checked October 29, 2026. Taxes and shipping additional. Final pricing and availability are shown on Pepetools.com.

06 / THE TECHNICAL DETAILS

80A specifications.
All in one place.

80A controls and electrical specifications from the operation manual (version 1.1), with the 950W limit confirmed by Pepetools. Dimensions below use Pepetools’ larger published measurements. Request separate electrical specifications for the 60A model.

View the manufacturer’s listing
Maximum current / voltage
80A max / 18V max, subject to the power limit
Maximum output power
950W — current × voltage must stay within this limit
Specified current range
0.35–80A
Current-limit setting
0–80A menu setting; 0.01A steps
Voltage setting
0.35–18V; 0.01V steps
Published accuracy
Voltage ≤0.2%; current ≤1%
Published ripple & noise
Voltage ≤1%; current ≤1%
Stored programs / sequence
5 programs; up to 5 sequence steps, with repeats allowed
Plating time per program
Up to 9h 59m; 1-second settings
Manual mode
Continuous operation; manual start/stop
Reverse-time setting
0–1h 29m 59s; 1-second steps
End-of-program delay
0–300 seconds; 1-second steps
AC input
Automatic 110/220V, 50/60Hz; ranges 105–132V / 200–248V
Dimensions (L × W × H)
Approx. 15.75 × 9.84 × 5.31 in
400 × 250 × 135 mm
Listed weight
6 kg / approx. 13.2 lb
Cooling / operating temperature
Forced air; +5°C to +40°C; keep vents clear
USB port
Firmware upgrades only
Protection features
Short-circuit, over-current and temperature shutoff
Included
Power cord, instructions, heavy-duty alligator-clip leads

07 / BUYER’S GUIDE

A few good questions.
Clearer answers.

Choosing a plating power supply starts with understanding what your process needs.

What does a plating rectifier do?

A plating rectifier converts AC input into a controlled DC supply for an electroplating process. The bath chemistry, part geometry and required current density help determine the current and voltage your setup needs. Programmable controls allow you to define electrical settings and timing for a run.

What does the amp-hour counter tell me?

It measures accumulated electrical charge: one amp maintained for one hour equals one amp-hour. This can help you track a run and follow a bath supplier’s amp-hour-based maintenance guidance. It does not directly measure coating thickness or prove metal savings. Current efficiency, plated area, chemistry and other factors still matter.

Should I choose a 60A, 80A or smaller rectifier?

Calculate current from the total plated surface area and the current density specified by your chemistry supplier. Then confirm required voltage, minimum current, operating duration and suitable margin. Consider IPS for lower-current requirements, and evaluate Digital Precision when your process needs more capacity. The shared Digital Precision listing explicitly specifies 80A at 18V; ask Pepetools for separate 60A voltage and operating specifications.

How do sequential programs help with copper via filling?

Sequence mode lets you arrange up to five stored programs in order and reuse a program in more than one step. Each program can have its own voltage, current limit, plating time, reverse time and end-of-program delay. That supports staged electrical settings for copper via-fill development and other multi-stage plating processes. Use a sequence qualified for your chemistry, via geometry and agitation; sequencing alone does not guarantee filling performance or establish high-frequency pulse capability.

For background on the distinct DC and reverse-pulse approaches used in copper filling, see Atotech’s copper plating overview ↗.

What does the 950W limit mean for the 80A model?

The supply has separate maxima of 80A and 18V, with a total output-power ceiling of 950W. Power equals voltage × current, so 80A at 18V would exceed that ceiling. At 80A, the power limit corresponds to about 11.9V; at 18V, it corresponds to about 52.8A. These are calculated power-limit boundaries, not additional performance guarantees. Match the actual voltage and current your bath needs to all three ratings.

Can I use this rectifier for electroforming?

Yes, when its electrical range matches your electroforming bath and workpiece. Manual mode can run continuously without a programmed time limit, making it useful for extended copper electroforming runs. The 9h 59m setting applies to the plating time within an individual program. Up to five stored programs can also run in sequence for processes that need staged settings. For the 80A model, check the 18V maximum, the 950W total power limit and the specified 0.35–80A operating range against your process.

Does reverse polarity mean high-frequency pulse plating?

Sequence mode runs complete stored programs in a selected order. The manual documents timed polarity reversal and 1-second timing adjustments; it does not specify a high-frequency pulse waveform. If a copper via-fill or other process requires millisecond pulses, a particular frequency or pulse width, verify those requirements with Pepetools before selecting the supply.

Will it work for anodizing or electrocoating?

Do not assume compatibility from the current rating. Some anodizing and electrocoating processes need voltages beyond the 80A model’s published 18V rating. Provide your chemistry supplier’s complete electrical requirements so the correct equipment can be identified.

What else do I need for a plating setup?

The Digital Precision listing includes the rectifier, power cord, instructions and heavy-duty alligator-clip leads. Tanks, chemistry, anodes, part fixtures, preparation equipment, and any heating, agitation or ventilation must be selected for your process. A rectifier is one component of a complete setup.

Can I use it outside the United States?

The manual specifies automatic 110/220V input selection at 50/60Hz, with input ranges of 105–132V or 200–248V. Confirm the circuit requirements, plug or cord arrangement and destination-specific documentation with Pepetools. Check current shipping options and charges for your country at checkout or with the team.

YOUR PROCESS. YOUR NEXT STEP.

Let’s find
your fit.

Tell us what you plate, your bath requirements and your batch size. We’ll help you evaluate the right Pepetools rectifier.